Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Monit Assess ; 195(11): 1307, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37831213

RESUMO

Radioactive elements and their impact on the environment and the food chain, including humans, are a matter of major concern, for which appropriate investigations should be performed. The priority is to examine the concentration of radioactive substances in mineral and bottled spring water. This task aims to analyze the quality of 12 conditioned mineral waters by determining their main radionuclides concentrations, such as 238U, 232Th, and 40K. The identification and the quantification of these radionuclides are carried out by their progeny (except the 40K) by using a NaI(Tl) detector coupled with a multichannel analyzer (MCA) and connected to a computer. The activity measured in all samples varied from 0.95 to 3.38 mBq.L-1 with an average of 1.94 mBq.L-1; from 1.55 to 3.56 mBq.L-1 with an average of 2.46 mBq.L-1; and from 200.68 to 269.19 mBq.L-1 with an average of 236.6 mBq.L-1, for 238U, 232Th, and 40K, respectively. To compare the combined radiological effects of radionuclides present in water, a particular factor Ra(eq) is used. This study showed that the maximum value of Ra(eq) is 27.54 mBq.L-1, which is far below the activity limit of 370 mBq.year-1 set by the Organization of Economics and Development (OECD). Concerning the effective annual dose, the following maximums were measured: 1.61 µSv.year-1, 1.133 µSv.year-1, and 0.925 µSv.year-1 for infants, children, and adults, respectively. These values are even smaller than the dose recommended by the WHO which is 100 µSv.year-1. Regarding the excess lifetime cancer risk index, a maximum of 5.63 × 10-6 is found. This index value is still less than that proposed by James, namely 2.5 × 10-3. Thus, the quality of the studied samples respects the radiological international safety and health limits.


Assuntos
Água Potável , Monitoramento de Radiação , Radioatividade , Poluentes Radioativos da Água , Lactente , Criança , Adulto , Humanos , Água Potável/química , Poluentes Radioativos da Água/análise , Espectrometria gama , Monitoramento de Radiação/métodos , Radioisótopos/análise
2.
Rep Pract Oncol Radiother ; 27(5): 832-841, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36523798

RESUMO

Background: Monte Carlo simulation is generally appreciated as an extraordinary technique to investigate particle physics processes and interactions in nuclear medicine and Radiation Therapy. The present task validates a new methodology of Monte Carlo simulation based on the Multithreading technique to reduce CPU time to simulate a 6 MV photon beam provided by the Elekta Synergy MLCi2 platform medical linear accelerator treatment head utilizing TOpas version 3.6 Monte Carlo software and the Slurm Marwan cluster. Materials and methods: The simulation includes the linear accelerator (LINAC) major components. Calculations are performed for the photon beam with several treatment field sizes varying from 3 × 3 to 10 × 10 cm2 at a 100 cm of distance from the source to the surface of the IBA dosimetry water box. The simulation was wholly approved by comparison with experimental distributions. To evaluate simulation accuracy, gamma index formalism for (2%/2mm) and (3%/2mm) criteria, Distance To Agreement DTA, and the estimator standard error ɛ and ɛ max are used. Results: Good agreement between simulations and measurements was observed for depth doses and lateral dose profiles, respectively. The gamma index comparisons also highlighted this agreement; more than 97% of the points for all simulations satisfy the quality assurance criteria of (2%/2mm). Regarding calculation performance, the event processing speed is faster using Gate-[mp] compared to TOpas-[mt] mode when running the identical simulation code for both. Conclusions: Consequently, according to the achieved results, the proposed methodology shows the first validation of TOpas in radiotherapy linacs simulations and a reduction in calculation time, capping simulation accuracy as much as possible. For this reason, this software is recommended to be serviceable for Treatment Planning Systems (TPS) purposes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...